Inspection Standards
State of Nevada Statutes/Administrative Code Standards
(NRS 645D) & (NAC 645D)
Click here to view Click her to view
ASHI Standards of Practice
Click here to view
Combined in
Argyll & Sutherland, Ltd. Report Category Format
INTRODUCTION
Describe scope and conditions
GRADING & EXTERIOR
Inspect walls, flashing, and trim
grading and vegetation
retaining walls if affect main structure
Describe eaves, soffits, and facia (trim) (Inspect from the ground)
wall coverings
roof drainage
doors and windows
walks, drives, patio, porches and contiguous structures,
and their railings
Report water penetration and abnormal or harmful condensation
GARAGE
Inspect garage doors and openers
Describe garage and carport structure
visible structural damage
Report water penetration and abnormal or harmful condensation
FOUNDATION & STRUCTURE
Inspect sumps, pumps, and lines
Describe crawl space inspection (access)
foundation
floor structure
wall structure
ceiling structure
visible structural damage
Report water penetration and abnormal or harmful condensation
Probe materials with suspected damage (where probing will not
damage further)
ROOF
Describe surface inspection (access)
attic inspection (access)
roof cover
roof structure
flashing
skylights chimneys penetrations
visible structural damage
Report water penetration and abnormal or harmful condensation
Inspect ventilation in the attic and foundation areas
mechanical ventilating systems
Describe insulation and vapor barriers in unfinished spaces
roof vents
absence of insulation in unfinished areas at conditioned
surfaces
Report water penetration and abnormal or harmful condensation
Operate attic fans and thermostatic controls (where temperature
allows)
INTERIOR
Inspect walls, ceilings, floors
steps, stairs, railings
countertops and representative number of cabinets
fireplaces and solid fuel device vents, flues, and
chimneys
Describe fireplaces and solid fuel devices and their chimneys
Report absence of smoke detectors
abnormal or harmful water penetration
Operate a representative number of doors and windows
PLUMBING
Inspect fuel storage, distribution, and lines
Describe water, waste, and vent lines
water heater type and energy source
location of main shutoff valves for water and gas
Report water penetration and abnormal or harmful condensation
Operate faucets and fixtures
Determine fundamental flow of waste system
ELECTRICAL
Inspect service drop
service panel and interior components
sub-panel
entrance conductors, cables, and raceways
compatibility of service protection devices
readily accessible wiring and junction boxes
Describe breakers, fuses, or other protection devices
amperage and voltage
location of main and sub panels
location of main disconnect
ground
wiring methods
Report the presence of solid aluminum branch conductors
Test a representative number of readily accessible light fixtures,
switches, and receptacles
CENTRAL HEATING
Inspect ducts, flues, and chimneys
controls
distribution components
auxiliary equipment
Describe equipment by distinguishing characteristics (open
readily openable access panels)
energy source
CENTRAL AIR CONDITIONING
Describe installed and through wall A/C and cooling equipment
by distinguishing characteristics (open readily openable
access panels)
energy source
BUILT-IN APPLIANCES
Inspect built-in dishwasher, range, cooktop, oven, garbage
disposal, microwave, and trash compactor
Operate dishwasher through a Normal cycle
NOTE: Describe and Report automatically include Inspect.
Our Inspections & Reports exceed these standards.
|