Inspection Standards

 

State of Nevada Statutes/Administrative Code Standards

(NRS 645D) & (NAC 645D)

Click here to view Click her to view

 

ASHI Standards of Practice

Click here to view

 

Combined in

 

Argyll & Sutherland, Ltd. Report Category Format

  

INTRODUCTION

 

Describe scope and conditions

 

GRADING & EXTERIOR

 

Inspect walls, flashing, and trim

          grading and vegetation

          retaining walls if affect main structure

 

Describe eaves, soffits, and facia (trim) (Inspect from the ground)

          wall coverings

          roof drainage

          doors and windows

          walks, drives, patio, porches and contiguous structures,

           and their railings

 

Report water penetration and abnormal or harmful condensation

 

GARAGE

 

      Inspect garage doors and openers

 

      Describe garage and carport structure

                visible structural damage

 

      Report water penetration and abnormal or harmful condensation

 

FOUNDATION & STRUCTURE

 

Inspect sumps, pumps, and lines

 

Describe crawl space inspection (access)

          foundation

          floor structure

          wall structure

          ceiling structure

          visible structural damage

 

Report water penetration and abnormal or harmful condensation

 

Probe materials with suspected damage (where probing will not

            damage further)

 

ROOF

 

Describe surface inspection (access)

          attic inspection (access)

          roof cover

          roof structure    

          flashing

          skylights   chimneys    penetrations

          visible structural damage

 

Report water penetration and abnormal or harmful condensation

 

Inspect ventilation in the attic and foundation areas

          mechanical ventilating systems

 

Describe insulation and vapor barriers in unfinished spaces

          roof  vents

          absence of insulation in unfinished areas at conditioned

           surfaces

 

Report water penetration and abnormal or harmful condensation

 

Operate attic fans and thermostatic controls (where temperature

           allows)

 

INTERIOR

 

Inspect walls, ceilings, floors

          steps, stairs, railings

          countertops and representative number of cabinets

          fireplaces and solid fuel device vents, flues, and

           chimneys

 

      Describe fireplaces and solid fuel devices and their chimneys

 

      Report absence of smoke detectors

                abnormal or harmful water penetration

 

      Operate a representative number of doors and windows

 

PLUMBING

 

Inspect fuel storage, distribution, and lines

 

Describe water, waste, and vent lines

          water heater type and energy source

          location of main shutoff valves for water and gas

 

Report water penetration and abnormal or harmful condensation

 

Operate faucets and fixtures

 

Determine fundamental flow of waste system

 

ELECTRICAL

 

Inspect service drop

          service panel and interior components

          sub-panel

          entrance conductors, cables, and raceways

          compatibility of service protection devices

          readily accessible wiring and junction boxes

 

Describe breakers, fuses, or other protection devices

          amperage and voltage

          location of main and sub panels

          location of main disconnect

          ground

          wiring methods

 

Report the presence of solid aluminum branch conductors

 

Test a representative number of readily accessible light fixtures,

            switches, and receptacles

 

CENTRAL HEATING

 

Inspect ducts, flues, and chimneys

          controls

          distribution components

          auxiliary equipment

 

Describe equipment by distinguishing characteristics (open

            readily openable access panels)

          energy source

 

CENTRAL AIR CONDITIONING

 

Describe installed and through wall A/C and cooling equipment

            by distinguishing characteristics (open readily openable

            access panels)

          energy source

 

BUILT-IN APPLIANCES

 

Inspect built-in dishwasher, range, cooktop, oven, garbage

            disposal, microwave, and trash compactor

 

Operate dishwasher through a Normal cycle

 

NOTE: Describe and Report automatically include Inspect.

 

Our Inspections & Reports exceed these standards.


Argyll & Sutherland Ltd. Po Box 19700 Reno, NV 89511-2408
Phone: Fax:

Contact Us | New Construction | Inspection Report | Home Page | Comments/Questions | Helpful Links | Re-inspections | About Us | Inspection Standards | Partial Inspections | Buyer Checklist | Download Adobe Acrobat | Tell a Friend | Real Estate News | FAQ | Glossary of Terms | Common Defects | Newly Built Homes | Buyer's Inspection | What is an Inspection | Seller's Inspection